Number of VCM Managed
Machines
RAID Channel and RAID Level Partitions Usable
Space
1–500 Channel 0 RAID 1 OS 36GB
Collector Data
Files
36GB
TempDB 36GB
SQL Log Files 28GB
Channel 1 RAID 0+1 (recommended) or
RAID 10
SQL Data Files 56GB
501–1000 Channel 0 RAID 1 OS 36GB
Collector Data
Files
36GB
Channel 1 RAID 1 TempDB 56GB
SQL Log Files 56GB
Channel 2 RAID 0+1 (recommended) or
RAID10
SQL Data Files 113GB
1001–2000 Channel 0 RAID 1 OS 36GB
Collector Data
Files
54GB
Channel 1 RAID 1 TempDB 113GB
Channel 2 RAID 1 SQL Log Files 113GB
Channel 3 RAID 0+1 (recommended) or
RAID 10
SQLData Files 227GB
2001–5000 Channel 0 RAID 1 OS 36GB
Collector Data
Files
113GB
Channel 1 RAID 1 TempDB 227GB
Channel 2 RAID 1 SQL Log Files 227GB
Channel 3 RAID 0+1 (recommended) or
RAID 10
SQLData Files 456GB
Table 27. Minimum Disk Configuration Requirements by Number of Managed Machines