VMware NetApp FAS 2050HA Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Logiciel de gestion de la sécurité VMware NetApp FAS 2050HA. DEPLOYMENT GUIDE Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 21
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Vue de la page 0
1 2 3 4 5 6 ... 20 21

Résumé du contenu

Page 2

Physical AdaptersPhysical AdaptersVM NetworkVMkernel NFS192.168.1.101Service Consolevswif0: 10.10.10.10Virtual Switch: vSwitch2VMkernel Port ESX Ho

Page 3 - 2 ABOUT THIS GUIDE

Storage required after deduplication 5GB Number of volumes used 1 (Single parent VM will be used for both PODs) Size of VM 10GB Volumes for Linked

Page 4 - Table 1: Glossary of terms

To configure the volumes that will contain the virtual machines perform the following steps: 1. For each NetApp controller, open NetApp FilerView

Page 5

You will next need to ensure that three of the volumes created on the storage controller are set as NFS volumes. In order to accomplish this, pleas

Page 6 - 4 PHYSICAL ARCHITECTURE

4.4 INTELLIGENT READ CACHING VDI by nature is a read-intensive technology and is very bursty in nature. This can be exemplified by boot storms, lo

Page 7

4.6 VMWARE ESX CONFIGURATION Each VMware ESX server should be configured to maximize NFS throughput and capability. In order to maximize NFS capabi

Page 8

Figure 7) ESX Host NFS Network Configuration Figure 8) ESX Host NFS Load Balancing Network Configuration 15

Page 9

The NFS datastores will need to be mounted on each of the ESX hosts. Please follow the below steps to mount NFS datastores on the ESX host server.

Page 10 - ESX Host

0.00 0.50 1.00 1.50 2.00 2.50ACROBAT_OPEN_1EXCEL_OPEN_1EXCEL_OPEN_2EXCEL_SAVE_1EXCEL_SAVE_2FIREFOX_CLO SEFIREFOX_OPENIE_OPEN_1IE_OPEN_2PPT_APPENDPPT

Page 11

Figure 11) NetApp FAS2050 controller B average NFS OP Rate 6 SUMMARY This reference architecture deployment guide details and validates a 1000 seat

Page 12

Contents 1 IntroductiontoVMwareView...2 2 AboutThisGuide...

Page 13

19VMware View Composer Deployment Guide VMware View Reference Architecture

Page 15

1 INTRODUCTION TO VMWARE VIEW Built on VMware’s industry-leading virtualization platform, VMware® View is a Universal Client solution that lets you

Page 16

NFS Network File System Protocol NIC Network Interface Card RAID Redundant Array of Independent Disks Snapshot Read only copies of an entire file

Page 17 - 5 VALIDATION RESULTS

Ten Servers (Configured as follows) 128 GB RAM 4 Quad Core Xeon Processors 2 On-board Ethernet NICs 2 Quad port Ethernet NICs Table 2: Hard

Page 18

Table 3) Software Resources 4 PHYSICAL ARCHITECTURE Figure 1) Physical Architecture Overview. 4.1 NETWORK ARCHITECTURE The networks used for this

Page 19 - 8 REFERENCES

Teaming ports and assigned to the public VLAN for access to CIFS shares and other network resource by the desktop virtual machines. The NetApp FAS2

Page 20

reboot of the storage controller at a future time. In the event the management/CIFS VIF needs to be created after the initial setup of the FAS2050,

Page 21

Figure 4) FAS2050 NFS VIF setup – Modify virtual interface. The ESX hosts will need to be configured as well. For each ESX host, configure NFS conn

Commentaires sur ces manuels