VMware VCENTER CONFIGURATION MANAGER FOUNDATION CHECKER 3.0 Guide d'installation Page 71

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 229
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 70
Related Products / Related
Functionalities
Hardware Parts Status Name
NEC ESMPRO Battery / Boot Error / Button/Switch / Cable/Interconnect /
Chassis / Chip Set / ClusterLan / ClusterNode / Cooling Device
/ CpuDegeneracy / CpuLoad / Critical Interrupt / DeadOrAlive /
Disk / DiskRecovery / DiskReplace / Drive Slot(Bay) / Entity
Presence Information / Event Logging / Fan(Speed) /
Management Subsystem Health / Memory /
MemoryDegeneration / Module/Board(Missing) / OS Boot / OS
Critical Stop / Physical Security(Chassis Intrusion) / POST
Error / POST Memory Resize / Power Supply / Power Unit /
Processor / Slot/Connector / System ACPI Power State /
System Event / Temperature / Voltage / Watchdog1
Out-of-Band Management
(Sensor)
Battery / Button/Switch / Cable/Interconnect / Chassis / Chip
Set / Cooling Device / Critical Interrupt / Drive Slot(Bay)/ Entity
Presence Information / Event Logging / Fan(Speed) / LAN /
Management Subsystem Health / Memory /
Module/Board(Missing) / Monitor ASIC/IC / OS Critical Stop /
Physical Security(Chassis Intrusion) / Platform Security
Violation Attempt / POST Error / POST Memory Resize / Power
Supply / Power Unit / Processor / Slot/Connector / System
ACPI Power State / System Event / Temperature / Voltage /
Watchdog1 / Other Units-based Sensor / Other FRU /
Watchdog Timer / Microcontroller/Coprocessor / Add-in Card /
Terminator / System Boot Initiated / Platform Alert / Session
Audit / Version Change / FRU State / OEM
Hyper-V NetworkInterface / Node / Resources (VM) / OSStatus /
DiskAccess
VMware (ESX, ESXi) Connection State / Cpu Usage / Heartbeat State / Memory
Usage / Network Connectivity / Power State / Storage Path
Connectivity / OSStatus / DiskAccess
Citrix XenServer OSStatus / DiskAccess
Alive Monitoring AliveMonitoringState / PingState / PortConnectivity
Hardware parts statuses of NEC ESMPRO and Out-of-Band Management do not
recover automatically because SigmaSystemCenter cannot realize the target machine
is in normal status unless the sensor diagnosis is executed.
Therefore, enable Out-of-Band Management to use Total recover diagnosis, execute
Composite Diagnosis in the Web Console, or execute Reset(Ready) manually.
As for the following hardware parts statuses, they do not recover to Normal
automatically. Check that the target machine has no abnormalities, and execute
Reset(Ready) manually.
Hardware Parts
Status Name
Status Corresponding Event
ClusterLan Faulted [Source]CLUSTERPRO [ID]0xC0005217(21015)
[Summary]Public LAN error
[Source]CLUSTERPRO [ID]0xC000521B(21019)
[Summary]Public LAN error
[Source]CLUSTERPRO [ID]0xC000521C(21020)
[Summary]Public LAN error
[Source]CLUSTERPRO [ID]0xC000521D(21021)
Vue de la page 70
1 2 ... 66 67 68 69 70 71 72 73 74 75 76 ... 228 229

Commentaires sur ces manuels

Pas de commentaire