Adding in Datastores Section 12 Storage Area Network
120 3BSE056141-510 F
In the network performance chart below, the 4 network adapters that are supporting
the SAN server 1,3,4,7 (Figure 44) are all providing throughput to the SAN sever.
If the configuration is not correctly setup, not all the network connections used for
communication with the SAN server. It displays the network traffic. It is important
to check the average/maximum values as there may be instances where the network
traffic was sampled when there was no traffic.
The following are the areas that must be checked:
Are the network switches in the ESX(i) server configured correctly.
Are the VLANs setup correctly in the ESX(i) server and the SAN server.
Can the SAN server be pinged on each of the IP addresses from the ESX(i)
server. Note that vmkping is used from the console of the ESX(i) server.
Is it iSCSI Path Selection Policy set to Round Robin.
Figure 44. Load balancing of SAN Servers