Figure 64: Site 1 vCenter inventory cleanup
8. Create protection group at Site 2 for datastore group containing the NFS export. Follow the usual
9. Create Recovery plan at Site 1 for the protection group created in step 8. Follow the usual steps to
create a recovery plan at Site 1 that maps to the protection group you are going to failback.
10. Review configuration then test recovery plan using Site Recovery Manager “Test” mode recovery
plan functionality
often overlooked is the ability to test your failback in the same way as you can test recovery before
failing over. The ability to test and re-test failback should be used for every failback operation you
perform. Best practice: do not attempt any failback unless a successful test has been performed.
NOTE: If you wish to test failback prior to actually running the failback check with your storage team
that the appropriate functionality is in place on the target storage array to allow the test to take place,
Before failback review the configuration of the Site 2 - now the protected site - Site Recovery Manager
find that you have a protection group object, configured array manager and inventory mappings as
illustrated in Figure 65