OneCommand™ Manager Application P007997-01A Rev. B
8. Managing Adapters and Ports
OneConnect Adapters
160
Exceeded operational range – Critical: The adapter’s temperature is beyond
normal operational range. If the temperature continues to increase, the
adapter shuts down. You must determine the cause of the temperature
problem and fix it immediately. Check for system cooling issues. Common
causes of system cooling issues include clogged air filters, inoperable fans
and air conditioning problems that cause high ambient air temperatures.
Exceeds operational range: The temperature has reached critical limit. You
must determine the cause of the temperature problem and fix it before
resuming operation. Check for system cooling issues. Common causes of
system cooling issues include clogged air filters, inoperable fans and air
conditioning problems that cause high ambient air temperatures.
After the system overheating issue is resolved and the adapter has cooled
down, reboot the system or, if the system supports hot swapping, cycle the
power of the adapter slot.
Personality Area
Current – The current personality in use by the adapter.
After Reboot
FCoE – Check to choose the FCoE personality.
iSCSI – Check to choose the iSCSI personality.
NIC Only – Check to choose the NIC only personality
Note: Some of the personalities may be disabled if the personality is not
available on the adapter.
Apply button – Click to apply the personality you choose. The system must be
rebooted for your selection to take affect.
License Features Area
Show License Features button – Click to show available licenses. See “Showing
and Installing Licenses for OneConnect Adapters” on page 161 for more
information.
Install License Features button – Click to install licenses. See “Showing and
Installing Licenses for OneConnect Adapters” on page 161 for more
information.
Viewing OneConnect Multi-ASIC Adapter Information
When you select a OneConnect multi-ASIC adapter from the discovery-tree, the
Adapter Information tab contains general attributes associated with the selected dual
ASIC four-port OneConnect adapter.
To view general OneConnect multi-ASIC adapter information:
1. Select Host view.