OneCommand™ Manager Application P007997-01A Rev. B
14. Troubleshooting
Emulex Driver for Linux and OneCommand Manager Application Situations
215
Under certain conditions of an I/O load, some
targets cannot retire an I/O issued by a Linux
initiator within the default timeout of 30
seconds given by the SCSI midlayer. If the
situation is not corrected, the
initiator-to-target condition deteriorates into
abort/recovery storms leading to I/O failures
in the block layer. These types of failures are
preceded by a SCSI IO error of hex 6000000.
Emulex provides a script which addresses this issue. To access the
set_target_timeout.sh script, click
http://www.emulex.com/files/downloads/linux/tools.html, then
click the link to the appropriate driver, and click the Linux tools
link.
LPFC driver fails to recognize an adapter and
logs “unknown IOCB” messages in the system
log during driver load. The adapter is running
outdated firmware.
Update adapter firmware to minimum supported revision listed in
installation guide (or newer).
rmmod of LPFC driver hangs and module
reference count is 0.
Due to a small race condition in the kernel it is possible for an
rmmod command to hang. Issue the rmmod -w command. If this
does not help, reboot the computer.
System panics when booted with a failed
adapter installed.
Remove the failed adapter and reboot.
rmmod fails to unload driver due to device or
resource busy. This message occurs when you
attempt to remove the driver without first
stopping the OneCommand Manager
application, when the OneCommand Manager
application is installed and running or when FC
disks connected to a LightPulse adapter are
mounted.
Stop the OneCommand Manager application before attempting to
unload the driver. The script is located in the
/usr/sbin/ocmanager directory.
Type:
./stop_ocmanager
Unmount any disks connected to the adapter.
Unload the driver.
Type:
rmmod lpfc
Driver install fails. The lpfc-install script
fails to install the driver.
The install script may fail for the following reasons:
A previous version of the driver is installed. Run the
/usr/src/lpfc/lpfc-install --uninstall script and then try to
install the driver.
The current driver is already installed.
The kernel source does not match the standard kernel name or
you are running a custom kernel.
“No module lpfc found for kernel” error
message. When updating the kernel, rpm
generates the following error: “No module lpfc
found for kernel KERNELVERSION”.
A recently updated kernel cannot find the
ramdisk. After updating the kernel, the kernel
cannot find the ramdisk which halts or panics
the system.
The driver is not loaded after a system reboot
after updating the kernel.
These three situations may be resolved by updating the kernel.
There are two ways to install the driver into an updated kernel.
The method you use depends on whether or not you are updating
the driver.
Update the kernel using the same version of the driver.
Update the kernel using a new version of the driver.
See the Installation section of the driver manual for these
procedures.
Table 14-2 Emulex Driver for Linux and OneCommand Manager Application Situations (Continued)
Situation Resolution